10kv High Voltage Test And Measurement Equipment , High Grade Meter Test Bench For Ring Main Unit

Brand Name : KRE

Model Number : KE9806

Certification : ISO9000

Place of Origin : China

MOQ : 1 piece

Payment Terms : Western Union, L/C, T/T, D/P, D/A, MoneyGram

Supply Ability : 50 pieces per month

Delivery Time : 30 days

Packaging Details : Plywood case

Current range : 0.01 - 1000A

Warranty : 12 months

Accuracy : 0.05

Voltage output : 0V - 10kV

test object : ring main unit (RMU)

Standard : IEC

Phase : Three

Contact Now

10kv High Voltage RMU Test Equipment for Ring Main Unit high grade 0.05 1000A

KE9806 10kv High Voltage RMU Test Equipment

KE9801 can simulate user's on-site environment for testing and inspection. It is mainly used to calibrate the error of ring main unit and verify whether the product's functions conform to national standards and industry standards.

Basic functions:

  1. Overall error calibration and metrological verification of RMUs.
  2. 10kV measurement box (cabinet) overall error calibration and measurement verification.
  3. Error calibration and metrological verification of distribution line loss acquisition module.
  4. Overall error calibration and metrological verification of weak output combined transformer and weak input energy meter.
  5. Calibration of electromagnetic transformer, electronic transformer, multi-ratio transformer.

Test items:

  1. Basic error, creeping test, starting test, time and date, constant check, standard deviation, 485 communication, voltage, current, power factor, frequency error detection.
  2. Zero-sequence voltage, zero-sequence current, active power, and reactive power error detection.
  3. Harmonic influence error detection.
  4. Telemetry detection: current, voltage, power due to numerical detection, increase the amount of comparison, the program can set the load point, verification time and so on.
  5. Remote detection: switch on and off test
  6. Remote signal detection: cooperates with remote control detection to test FTU (DTU) communication and other functions.
  7. Fault current detection: add overload current to the switch that sets the current value, and test whether the switch responds to overcurrent alarm.
  8. Protection testing: first overcurrent detection and second overcurrent detection.
  9. The power source can simulate the zero-sequence voltage and current and output them.
  10. Test of transformer angle difference and ratio error(optional function).
  11. Simulated short-circuit ground fault test, typical small-current single-phase metal grounding, low-impedance single-phase grounded, high impedance single-phase ground wave output (optional function).
  12. Automatic generation of test reports.

Main Specification:

Accuracy

Overall active energy

± 0.05%

Overall reactive energy

± 0.05%

Voltage transformer

± 0.02%

Current transformer

± 0.01% (50mA – 1000A)

Three phase reference meter

± 0.05%

Voltage output

Rated value(P-N)

57.7V,11.54kV

Rated value(P-P)

20kV

Output power (per phase)

600VA

Adjust range

0%~120%

Resolution

10%,1%,0.1%,0.01% and stepless regulation

Load characteristic

Resistive, capacitive, inductive
Rated output value of voltage transformer 5.77kV/57.7V,11.54kV/57.7V

Current output

Output range (per phase)

10mA – 1000A

Output power (per phase)

2000VA

Adjust range

0%~120%
Resolution 10%,1%,0.1%,0.01% and stepless regulation

Load characteristic

Phase output

Output range

0 -- 360°
Resolution 10°,1°,0.1°,0.01° and stepless regulation

Frequency output

Output range

45Hz – 65Hz
Resolution 10Hz,1Hz,0.1Hz,0.01Hz and stepless regulation

Inner insulation

Between high voltage and low voltage 30kV PF voltage per minute

Operating condition

Power supply

3×220/380V±10%,50/60Hz±2Hz

Max power consumption

10kVA

Environment temperature

-10°C -- +40°C

Environment humidity

35% -- 85%

Other

Product dimensions

Separated type:
lower side 575mm ×1000mm × 2276mm
higher side 1415mm x 1518mm x 2276mm

integral mobile type:
1420mm x 1000mm x 1700mm

Weight

Separated type:
lower side 500kg
higher side 450kg


Integral mobile type:
850kg

10kv High Voltage Test And Measurement Equipment , High Grade Meter Test Bench For Ring Main Unit


Product Tags:

energy meter test bench

      

meter test system

      

10kv Energy Meter Testing Equipment

      
Quality 10kv High Voltage Test And Measurement Equipment , High Grade Meter Test Bench For Ring Main Unit for sale

10kv High Voltage Test And Measurement Equipment , High Grade Meter Test Bench For Ring Main Unit Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou Kingrise Enterprises Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)